Re: Home ethernet

sjk <[email protected]>
Newsgroups gmane.org.user-groups.luni.tech
Message-ID <[email protected]>
Yes, what is referred to as the Distribution Frame. I would avoid
termination in a boiler/furnace area, as you will likely be placing
active equipment there, and any additional heat will shorten the
lifespan of the equipment. I don't know the layout of your home, but you
probably want to look for a closet or office space with at least ~80
cubic feet. Your electrician will be placing pipe for high voltage - do
not run the Ethernet in the same pipe. Place it along side the pipe, or
against a stud and bring it out a mudring or j-box.

On 03/06/2011 09:42 PM, Larry Garfield wrote:
> By MDF you mean the place where the lines all come together in the switch, aka 
> wiring closet, I presume?  At present I'm looking at putting that in the 
> utility room with the furnace and water boiler since there should be plenty of 
> space, although thinking about that now I'm wondering if that would be too 
> warm.  Any recommendations?
> 
> I am not sure if the electrician is planning on putting in pipe or not.  My 
> contractor didn't say.  The price he quoted was higher than I expected so he 
> may be.  OTOH, I did map out 1-2 jacks per room for flexibility so that I can 
> rearrange furniture later as the situation requires, so 12 lines total for the 
> house.  I'm pretty sure I won't be exceeding any distance limitations as it's 
> only a single family home.
> 
> --Larry Garfield
> 
> On Sunday, March 06, 2011 9:16:46 pm sjk wrote:
>> Yes, do it now while your walls are open. Unless you plan on piping
>> everything the cost will be minimal. I would probably pull CAT6 at this
>> point and terminate it with the cheaper CAT5e panels and inserts for the
>> time being. The bigger issue is locating and designing your MDF. Make
>> sure it has enough ventilation and power and that the drops do not
>> exceed any distance limitations. When choosing your drops make
>> allowances for future multi-media and VoIP equipment.
>>
>>
>> programming geek, so I'm a bit out of my element here.  Any advise or
>> experience anyone has to share would be most appreciated.
>>
>> On 03/06/2011 07:45 PM, Larry Garfield wrote:
>>> programming geek, so I'm a bit out of my element here.  Any advise or
>>> experience anyone has to share would be most appreciated.

-- 
http://www.sleepycatz.com
[email protected]
fingerprint: 1024D/89420B8E 2001-09-16
-- 
Linux Users Of Northern Illinois (Chicago) - Technical Discussion 
http://luni.org/mailman/listinfo/luni
lmpx.com only provides a reader for public news (NNTP) servers. It is not affiliated with the servers or forums shown here and is not responsible for the content of articles, which is written by their respective authors.