Re: Looking for V210/V240 testers
Julian Coleman <[email protected]> Mon, 2 Mar 2026 11:38:51 +0100
| Newsgroups | gmane.os.netbsd.ports.sparc64 |
|---|---|
| Message-ID | <[email protected]> |
Hi, > Here's my v210: Thanks for the output! > Current CritMax WarnMax WarnMin CritMin Unit > [adm1026hm0] > Vbatt: 0.518 4.000 V > Guess I need to look at the battery... By default, there isn't a low/WarnMin limit here, so you don't get a console warning. It does look like it needs a new battery though! > I didn't enable the rtc at ebus yet, will check that one later. The default RTC at ebus should already be enabled. We don't enable the rscrtc at iic0 by default though. At the start of: https://ftp.netbsd.org/pub/NetBSD/misc/jdc/sparc64/u45.diff are changes for kern_todr.c and GENERIC so that we can have 2 clocks. I haven't tested the latest changes there though, which output if the clocks have different times. I'll be away from my machines for about a week, so I can't test just yet (it should work on E250 and V2x0). Regards, Julian --