Re: P4 on sun3/sun3x (Re: NetBSD/sun3 10.0_RC2 problems on sun 3/60)

Michael Thompson <[email protected]> Fri, 19 Jan 2024 10:15:43 -0500
Newsgroups gmane.os.netbsd.ports.sun3
Message-ID <[email protected]>
One on my 3/80 burned, but the system never stopped and still works OK.

> On Jan 19, 2024, at 8:28 AM, Izumi Tsutsui <[email protected]> wrote=
:
>=20
> romain@ wrote:
>=20
>>> There's a specific tantalum capacitor in one corner of the logic board t=
hat *always* blows on the 3/80, and the suggestion I received from numerous p=
eople after mine blew was to just desolder the remnant and remove it, and no=
t to bother replacing. I believe they said it's just a filter cap that only r=
eally matters if you have super-noisy power or something like that.
>>=20
>> Oh, that's good news. The one that blew is C1719 (closest to the angle
>> with the PS connector), is that the one you're talking about?
>=20
> Two tantalum caps on my 3/80 were also burnt in front of my eyes
> about 15 year ago.
>=20
> IIRC they were near the SCSI connector and I just replaced them
> and the 3/80 is still alive.
>=20
> The failure mode of tantalum caps is short mode and it could
> happen even on short time over voltage, so if its PSU has proper
> protection circuit, it's possible that "burning tantalum cap"
> might not cause other damages.
>=20
> Thanks,
> ---
> Izumi Tsutsui