Re: P4 on sun3/sun3x (Re: NetBSD/sun3 10.0_RC2 problems on sun 3/60)
Michael Thompson <[email protected]> Fri, 19 Jan 2024 10:15:43 -0500
| Newsgroups | gmane.os.netbsd.ports.sun3 |
|---|---|
| Message-ID | <[email protected]> |
One on my 3/80 burned, but the system never stopped and still works OK. > On Jan 19, 2024, at 8:28 AM, Izumi Tsutsui <[email protected]> wrote= : >=20 > romain@ wrote: >=20 >>> There's a specific tantalum capacitor in one corner of the logic board t= hat *always* blows on the 3/80, and the suggestion I received from numerous p= eople after mine blew was to just desolder the remnant and remove it, and no= t to bother replacing. I believe they said it's just a filter cap that only r= eally matters if you have super-noisy power or something like that. >>=20 >> Oh, that's good news. The one that blew is C1719 (closest to the angle >> with the PS connector), is that the one you're talking about? >=20 > Two tantalum caps on my 3/80 were also burnt in front of my eyes > about 15 year ago. >=20 > IIRC they were near the SCSI connector and I just replaced them > and the 3/80 is still alive. >=20 > The failure mode of tantalum caps is short mode and it could > happen even on short time over voltage, so if its PSU has proper > protection circuit, it's possible that "burning tantalum cap" > might not cause other damages. >=20 > Thanks, > --- > Izumi Tsutsui