Re: unstable C110
mickey <[email protected]> Wed, 20 Dec 2006 15:52:35 +0100
| Newsgroups | gmane.os.openbsd.hppa |
|---|---|
| Message-ID | <[email protected]> |
On Tue, Dec 19, 2006 at 10:26:56PM +0100, Maurice Janssen wrote:
> Hi,
re
> I have a C110 and I'm trying to install 4.0-release on it. However,
> I can't finish the install prodecure because the machine keeps locking
> up or panicing during the install.
> When I boot HP-UX (which is installed on the wide differential scsi
> drive) it seems to run fine (even though I can't do much because I don't
> have a login). Therefore, I think the hardware is OK.
>
> WHen I hookup a ordinary narrow SCSI drive and netboot the machine, the
> kernel usually loads fine. Sometimes it hangs at this point (the
> Install/Upgrade/Shell line never appears), sometimes it panics while
> formatting, sometimes it panics while installing the filesets, sometimes
> when setting up the network, but it never completes a full install.
have you tried snapshot or 3.9 by any chance?
i used to run it all the time and it was working fine.
will retry it someday.
> unknown Interphase device INP0500 at eisa0 slot 2 not configured
what is the interphase card in it btw?
cu
--
paranoic mickey (my employers have changed but, the name has remained)