Re: Fried SCSI controller?

Cody Swanson <[email protected]>
Newsgroups gmane.os.solaris.at-home
Message-ID <[email protected]>
On a sun system if you probe the scsi bus after a halt you will get a 
bus error. Try running a test scsi after a cold boot before the OS loads.


[email protected] wrote:
> Hi all.
> I got a Sun Enterprise 220R (2 X UltraSPARC-II 450MHz), with a pair of disks 
> to play with...  During boot I get "Bus fault" errors. The same occurs if I 
> stop the OS and test the SCSI subsystem. I am not sure it's a disk/cable or 
> controller (fried chip?) related problem.
>
> [root@db-1 root]# halt
> syncing file systems... done
> Program terminated
> {0} ok test scsi
> Bus fault
> Bus fault
> Bus fault
> ...
>
> I tried to disconnect the CDROM and to swap disks, but nothing changes.
>  What do you think? Thanks!
>
> --Tony
> _______________________________________________
> Suns-at-Home mailing list
> [email protected]
> http://www.net-kitchen.com/mailman/listinfo/suns-at-home
>
>