Re: Fried SCSI controller?

"rajnifft" <[email protected]>
Newsgroups gmane.os.solaris.at-home
Message-ID <000e01c83c47$a30d6dd0$650fa8c0@LocalHost>
Or do 'obdiag' from ok prompt and run through menu... " This is a hidden sun
nvram command, depend on the f/w ver(s)."

----- Original Message ----- 
From: "Cody Swanson" <[email protected]>
To: <[email protected]>
Cc: <[email protected]>
Sent: Sunday, December 09, 2007 11:03 AM
Subject: Re: [Suns-at-Home] Fried SCSI controller?


> On a sun system if you probe the scsi bus after a halt you will get a bus 
> error. Try running a test scsi after a cold boot before the OS loads.
>
>
> [email protected] wrote:
>> Hi all.
>> I got a Sun Enterprise 220R (2 X UltraSPARC-II 450MHz), with a pair of 
>> disks to play with...  During boot I get "Bus fault" errors. The same 
>> occurs if I stop the OS and test the SCSI subsystem. I am not sure it's a 
>> disk/cable or controller (fried chip?) related problem.
>>
>> [root@db-1 root]# halt
>> syncing file systems... done
>> Program terminated
>> {0} ok test scsi
>> Bus fault
>> Bus fault
>> Bus fault
>> ...
>>
>> I tried to disconnect the CDROM and to swap disks, but nothing changes.
>>  What do you think? Thanks!
>>
>> --Tony
>> _______________________________________________
>> Suns-at-Home mailing list
>> [email protected]
>> http://www.net-kitchen.com/mailman/listinfo/suns-at-home
>>
>>
>
> _______________________________________________
> Suns-at-Home mailing list
> [email protected]
> http://www.net-kitchen.com/mailman/listinfo/suns-at-home
lmpx.com only provides a reader for public news (NNTP) servers. It is not affiliated with the servers or forums shown here and is not responsible for the content of articles, which is written by their respective authors.