Re: Fried SCSI controller?
"ra2710" <[email protected]>
| Newsgroups | gmane.os.solaris.at-home |
|---|---|
| Message-ID | <001901c83c11$f38bb8b0$650fa8c0@LocalHost> |
Or do 'obdig' from ok prompt and run through menu... " This is a hidden sun nvram command, depend on the f/w ver." -robert astin ----- Original Message ----- From: "Cody Swanson" <[email protected]> To: <[email protected]> Cc: <[email protected]> Sent: Sunday, December 09, 2007 11:03 AM Subject: Re: [Suns-at-Home] Fried SCSI controller? > On a sun system if you probe the scsi bus after a halt you will get a bus > error. Try running a test scsi after a cold boot before the OS loads. > > > [email protected] wrote: >> Hi all. >> I got a Sun Enterprise 220R (2 X UltraSPARC-II 450MHz), with a pair of >> disks to play with... During boot I get "Bus fault" errors. The same >> occurs if I stop the OS and test the SCSI subsystem. I am not sure it's a >> disk/cable or controller (fried chip?) related problem. >> >> [root@db-1 root]# halt >> syncing file systems... done >> Program terminated >> {0} ok test scsi >> Bus fault >> Bus fault >> Bus fault >> ... >> >> I tried to disconnect the CDROM and to swap disks, but nothing changes. >> What do you think? Thanks! >> >> --Tony >> _______________________________________________ >> Suns-at-Home mailing list >> [email protected] >> http://www.net-kitchen.com/mailman/listinfo/suns-at-home >> >> > > _______________________________________________ > Suns-at-Home mailing list > [email protected] > http://www.net-kitchen.com/mailman/listinfo/suns-at-home