Hard Disk error alert veritas, solari

Darwin <[email protected]>
Newsgroups gmane.os.solaris.managers
Message-ID <CAJB2MDgw-v5sdguPtSQhQ5=e64A-7XqdBBj0oouKXionhXO_3Q@mail.gmail.com>
Hi , i have a server v440. i got following error in /var/adm/messages


Dec 12 20:03:36 devel01 scsi: [ID 107833 kern.warning] WARNING: /pci@1e
,600000/scsi@2/sd@3,0 (sd18):
Dec 12 20:03:36 devel01    Error for Command: write(10)               Error
Level: Retryable
Dec 12 20:03:36 devel01 scsi: [ID 107833 kern.notice]      Requested Block:
102607616                 Error Block: 102607635
Dec 12 20:03:36 devel01 scsi: [ID 107833 kern.notice]      Vendor: SEAGATE
                           Serial Number: 053980L3D7
Dec 12 20:03:36 devel01 scsi: [ID 107833 kern.notice]      Sense Key:
Hardware Error
Dec 12 20:03:36 devel01 scsi: [ID 107833 kern.notice]      ASC: 0x32 (no
defect spare location available), ASCQ: 0x0, FRU: 0x4

then i checked for iostat -En and grepped for partiucular slno of disk and
got  the following

c2t3d0           Soft Errors: 1 Hard Errors: 3 Transport Errors: 0
Vendor: SEAGATE  Product: ST314685LSUN146G Revision: 062D Serial No:
053980L3D7
Size: 146.80GB <146800115712 bytes>
Media Error: 0 Device Not Ready: 0 No Device: 0 Recoverable: 1
Illegal Request: 0 Predictive Failure Analysis: 1

Here the hard error is 3 and predictive failure analysis 1, is it good run
or go and replace the disk?

In veritas the disk is fine , if i put vxdisk list.. no failing , error msg.
lmpx.com only provides a reader for public news (NNTP) servers. It is not affiliated with the servers or forums shown here and is not responsible for the content of articles, which is written by their respective authors.