T2000 Spurious CPU Fan Fault
Nick Pettefar <[email protected]> Fri, 22 Mar 2013 13:09:56 +0000
| Newsgroups | gmane.os.solaris.managers |
|---|---|
| Message-ID | <CAA9hN5PHenBEbNoScr3z5oV3_nNLkKWEjka4Hr_sMR-kpOYNnQ@mail.gmail.com> |
We have a Sun Netra T2000 (Sun-Fire-T200 32 CPU) with 3 CPU fans, one of which is reporting a fault: ALOM> showfaults ID FRU Fault 0 FT0/FM2 SYS_FAN at FT0/FM2 has FAILED. ALOM> The machine is out of contract. I tried swapping the faulty CPU fan no. 2 for no. 1 and it still reports that fan no. 2 is faulty. I tried clearing the fault but it didn't seem to understand: ALOM> showfaults ID FRU Fault 0 FT0/FM2 SYS_FAN at FT0/FM2 has FAILED. ALOM> clearfault 0 Invalid UUID format. Error: Invalid command option Usage: clearfault <UUID> ALOM> ALOM> enablecomponent CH/FT0/FM2 Could not find asr-key CH/FT0/FM2 ALOM> The last message about the fan in the showfru command states: /Status_EventsR[9]/Message: SYS_FAN at FT2 is OK. I tried resetting the SC, power-cycling the whole machine and the clearasrdb command to no avail. prtdiag reports: ============================ FRU Status ============================ Location Name Status ------------------------------------------------------ 0707NNN065:CH/FT0/FM2 FAN disabled Does anyone have any suggestions? Regards, Nick Pettefar