Re: [Playerstage-users] Sick lms 291 - unable to use sick lms 200 driver

"Jack O'Quin" <[email protected]>
Newsgroups gmane.science.robotics.playerstage,gmane.science.robotics.playerstage.user
Message-ID <[email protected]>
2010/4/29 Víctor Costa <[email protected]>:
>
> Hi there everyone. Sorry for double mailing this, but there's been sometime
> that i don't send mails to the player lists and I forgot to which one I
> should be sending this. I've been having problems trying to connect to a
> sick lms 291 trhough player... I've tried using the sick lms 200 driver but
> I've had no  success. The driver hangs waiting for an ack signal from the
> laser after sending it to configuration mode and ultimately timeouts. Has
> anyone ever used this laser sensor with player before or has any idea on
> what the problem might be?

It works pretty well with that device for us. It does sometimes get
timeouts when first connecting on power-up. Almost always works OK
after that.

> The cfg file i've been using is the following:
>
> driver
> (
>   name "sicklms200"
>   provides [ "laser:0" ]
>   port "/dev/ttyUSB0"
>   resolution 50
>   range_res 10
>   serial_high_speed_mode 0
>   connect_rate [ 38400 ]
>   transfer_rate 38400
>   retry 5
>   alwayson 1
> )
>
> is there any changes needed on the original driver in order to use this?

Not that I know of.
-- 
 joq

------------------------------------------------------------------------------
lmpx.com only provides a reader for public news (NNTP) servers. It is not affiliated with the servers or forums shown here and is not responsible for the content of articles, which is written by their respective authors.