Re: [PATCH v2 6/6] arm64: dts: renesas: r8a78000: Add MDLC nodes

Marek Vasut <[email protected]>
Newsgroups org.kernel.vger.linux-renesas-soc,org.infradead.lists.linux-arm-kernel,org.kernel.vger.linux-clk,org.kernel.vger.linux-devicetree,org.kernel.vger.linux-kernel,org.kernel.vger.linux-pm
Message-ID <[email protected]>
On 7/9/26 12:24 PM, Geert Uytterhoeven wrote:

Hello Geert,

>>> +             mdlc_ddr7: system-controller@e8380000 {
>>> +                     compatible = "renesas,r8a78000-mdlc";
>>> +                     reg = <0 0xe8380000 0 0x1000>;
>>> +                     #power-domain-cells = <2>;
>>> +                     #reset-cells = <1>;
>>> +                     bootph-all;
>>> +             };
>>> +
>>> +             mdlc_hscn: system-controller@c9c90000 {
>>> +                     compatible = "renesas,r8a78000-mdlc";
>>> +                     reg = <0 0xc9c90000 0 0x1000>;
>>> +                     #power-domain-cells = <2>;
>>> +                     #reset-cells = <1>;
>>> +                     bootph-all;
>>> +             };
>>> +
>>> +             mdlc_rt: system-controller@19440000 {
>>
>> Please keep the list sorted (0x19440000 should be before 0xc9c90000).
> 
> These are sorted by instance (Module Number), as per Table 18.1
> ("Target Module hierarchy of Module Power Gating and Module Standby")
> in the documentation.  This order is indeed a bit odd, as it differs
> from both alphabetical label order (unlike e.g. hscifN), and numerical
> unit address order...
> 
> Any guidance?
Do you think those MDLC instances might be on different sub-busses and 
we might need to model those busses using simple-bus in DT ?
lmpx.com only provides a reader for public news (NNTP) servers. It is not affiliated with the servers or forums shown here and is not responsible for the content of articles, which is written by their respective authors.