[TME10}[ITM] omnibus SitForwarder

Yoganarasimha Iyengar <[email protected]>
Newsgroups gmane.comp.sysutils.tivoli.general
Message-ID <1F669BAC5FA4324594C896E6C522D8CA40AD58__18551.5760131695$1353679608$gmane$org@qssiex02.QSSI.CORP>
Hi,
This is issue related to  SitForwarder ( NC 731FP05 on RHEL 6, Hub and TEP all on separate box) 

1. I have setup ITM and Netcool event integration for bi-directional  per steps outlined  in IBM manual. 
On HUB enabled EIF integration and on TEP forwarding situation to EIF.

2. Inbound alerts reaching NC and can view them on NC Event console.

3. The problem is, alerts updated on NC Event console not reaching TEP.  I don't see any situation file under persistence directory except running .
Also files under /tmp/itmsynch/logs don't give much info though I have setup the log for verbose.

4. Another issue I notice  is in TEP, Omniconnector(common event console) status is always non-operational. Not sure both issues inter related . Hub and TEP are on separate RHEL box.

5. So far I have tried giving hostname and also IP in Omniconnector config but no luck

Thanks

Yoga Iyengar
Desk: (301)-977-7884 Ext. 199
Email: [email protected]