Re: Multiple Streams and mutiplex terminations
Javi Muñoz <[email protected]> Tue, 25 Oct 2011 13:51:48 +0200
| Newsgroups | gmane.ietf.megaco |
|---|---|
| Message-ID | <[email protected]> |
Hello Christian, Thank you for your answer. I understand MeGaCo syntax doesn't support adding streams in the multiplex descriptor neither including N in the multiplex descriptor. [Christian] A little, I understand the termination aspect. I'm still not sure about the streams. I don't understand how you can have multiple H.248 streams for the circuit termination TermA and TermB? With what information element (i.e. property) do you assign the SAPI and TEI to a Stream? What properties distinguish the Nx64K termination from a HDLCW1 one? [Christian] I'm not 100% sure what you're trying to do but if you're only using a single Termination to represent each D-channel and a single Termination for the HDLCPW it seems to me that you don't need a mux termination and that it may be sufficient to simply use a property to assign TEIs to Streams (or Terminations). [Christian] I think you're trying to solve this at a different level than what it should be. The multiplex descriptor describe the multiplex of terminations used to make up a stream. It doesn't describe what's happening at a stream level itself. We have the Stream Descriptor with associated (Local, Remote, LocalControl descriptors) to do this. In ISDN, each D-channel (channel of 16 or 64 kbps) transport multiple flows muliplexed by its TEI and SAPI in the Q.921 header. Every of these flows may need to be transported to a different server in the IP network, and each server may receive only a HDLCPW. So, I need to multiplex multiple D-channel flows in each HDLCPW. In each HDLCPW, each flow would be distinguished by its TEI/SAPI and D-channel identifier. I can not think how to describe in SDP (Local, Remote, LocalControl descriptors) what D-channel flows must be transported by any HDLCPW. May you proposed an example? Regards, Javier Muñoz >> >> >>> >>> >>> >>> Regards, >>> >>> Javi Muñoz >>> >>> >>> El 20/10/2011 11:12, Christian Groves escribió: >>>> Hello Javi, >>>> >>>> Did you see my email on the 18/10 which discusses this? Even with >>>> the clarification of the Terminations there's some questions. >>>> >>>> Regards, Christian >>>> >>>> On 20/10/2011 7:38 PM, Javi Muñoz wrote: >>>>> Does MeGaCo support the next contexts?: >>>>> >>>>> >>>>> >>>>> Tmux1=Mux(1x64K(TermA/StreamID=1,TermA/StreamID=2,TermB/StreamID=1)) >>>>> -- * -- TermC (HDLCPW1) >>>>> | >>>>> TermA (ISDN D-Channel, UNI p) | >>>>> StreamID=1 (SAPI 16, TEI r)------| >>>>> StreamID=2 (SAPI 16, TEI s)------| >>>>> | >>>>> TermB (ISDN D-Channel, UNI q) | >>>>> StreamID=1 (SAPI 16, TEI r)------| >>>>> StreamID=2 (SAPI 16, TEI s)------------| >>>>> StreamID=3 (SAPI 16, TEI t)------------| >>>>> | >>>>> >>>>> Tmux2=Mux(1x64K(TermB/StreamID=2,TermB/StreamID=3) -- * -- TermD >>>>> (HDLCPW2) >>>>> >>>>> >>>>> where: >>>>> >>>>> (a) Every multiplex termination is multiplexing Streams from >>>>> different ISDN terminations, and only any Streams of each >>>>> termination. >>>>> >>>>> (b) The result of the multiplexion must be a flow of "64 kbps". >>>>> >>>>> Javi Muñoz >>>>> _______________________________________________ >>>>> Megaco mailing list >>>>> [email protected] >>>>> https://www.ietf.org/mailman/listinfo/megaco >>>>> >>>> _______________________________________________ >>>> Megaco mailing list >>>> [email protected] >>>> https://www.ietf.org/mailman/listinfo/megaco >>>> >>> >>> >>