Haresign,

Yes, that is how it works.  Load selections are defined within an AS.
Therefore, the AS is on the basis of Point Code (and possibly SI=5).
CIC ranges are defined as load selectors and load selections are assigned
to ASPs serving the loadshare AS.  So, all ASPs in this example AS
would serve the same Point Code, but would be given traffic for different
CIC ranges.  Did you look at the draft?

--brian

Haresign Lincoln wrote:                      (Mon, 06 Nov 2006 16:10:12)
> Brian,
> 
> Is it possible using LOADSEL (or LOADGRP) to have two different
> Application Servers (not ASPs) handling different CIC ranges?  Both AS
> would share the same PC as the SG.  
> 
> Regards,
> Lincoln
> 

-- 