Re: help with firmware update on R610...
| Newsgroups | gmane.linux.hardware.dell.poweredge |
|---|---|
| Message-ID | <75F7F7632819D94BA80703D8B1F10B6D2A470998F0@BLRX7MCDC201.AMER.DELL.COM> |
Dell - Internal Use - Confidential Thanks for providing the log file . Please provide the operating system version details installed on your system. We will try to reproduce segmentation fault issue in the our lab. -----Original Message----- From: linux-poweredge-bounces-Lists On Behalf Of Bruce Ferrellngs Sent: Thursday, July 23, 2015 11:04 AM To: linux-poweredge-Lists Subject: Re: [Linux-PowerEdge] help with firmware update on R610... I have the same issue (symptom anyway) When I perform the steps outlined, sasdupie fails with a segmentation fault. inv.xml is zero length. debug.log is attached. No files in /var/log/dell/updatepackage/log/support/ sasdupie[20566]: segfault at 20 ip 00007f7c10ef500d sp 00007fff7703f950 error 4 in sasdupie[7f7c10ed0000+110000] On 07/22/2015 10:06 PM, [email protected] wrote: > > *Dell - Internal Use - Confidential * > > Hi Becky, > > > > Please provide logs from your system and following are steps to collect the debug logs . > > > > 1.Extract dup by running the command ".\SAS-RAID_Firmware_F96NR_LN_6.3.3-0002_X00.BIN--extract \tmp\dup_extract_dir" > > 2.Change to the extracted directory by running "cd \tmp\dup_extract_dir ". > > 4.Copy the payload directory up one level, "cp payload\* . " . > > 5.Run "sasdupie -i -o inv.xml -debug" for inventory > > 7.Send us files inv.xml, debug.log, package.xml and Dell customer logs > from > > /var/log/dell/updatepackage/log/ and /var/log/dell/updatepackage/log/support directories. > > > > Thanks > > Santosh > > > > *From:*linux-poweredge-bounces-Lists *On Behalf Of *Becky Ligon > *Sent:* Thursday, July 23, 2015 1:20 AM > *To:* linux-poweredge-Lists > *Subject:* [Linux-PowerEdge] help with firmware update on R610... > > > > All: > > When I run the firmware update for the PERC 6/i, I am getting this error: > > Collecting inventory... > ...... > Inventory collection failed. > > Where can I find information regarding this error? log files? Is it possible that the inventory collection system is not setup correctly on the machine? > > I am running SAS-RAID_Firmware_F96NR_LN_6.3.3-0002_X00.BIN. > > > > Any suggestions will be helpful! > > Becky > > > > -- > > Becky Ligon > Research Associate > Clemson University > Clemson, SC > > > > _______________________________________________ > Linux-PowerEdge mailing list > [email protected] > https://lists.us.dell.com/mailman/listinfo/linux-poweredge _______________________________________________ Linux-PowerEdge mailing list [email protected] https://lists.us.dell.com/mailman/listinfo/linux-poweredge