Re: Issue with replaced HD not coming on-line
Cameron Smith <[email protected]>
| Newsgroups | gmane.linux.hardware.dell.poweredge |
|---|---|
| Message-ID | <CABLobCOhZCf7r2NgFRyzaDwufXBa4Bb6QWM=Z-sqfS26OB=qfg@mail.gmail.com> |
I have seen similar issue when a SATA is mistakenly replaced for a SAS. If you have OMSA installed you can compare working drive details against this new drive with omreport commands. # omreport storage pdisk controller=0 |grep Bus Cameron Smith Technical Operations Manager Network Redux, LLC 5200 SW Macadam Ave Ste 450 Portland, Oregon 97239 Cell: 503-926-4928 On Fri, Oct 30, 2015 at 3:19 PM, Jeff Boyce <[email protected]> wrote: > Greetings - > > I have PET610 with a PERC H700 controller that a hard drive fail > recently. The drives are setup in a RAID5 (3 drives) with a single hot > spare. The hot spare was engaged and the failed drive was automatically > taken off-line after the virtual drive rebuild was completed. Today I > receive a replacement drive of the same specs as the failed drive > (manufacturer, model, etc.). I reviewed the instructions to replace the > drive, which were, > > 1. If drive is identified as off-line and the status lights on the > drive are out, manually pull the drive from the chassis. > 2. Unscrew and remove the failed drive from the carrier, and install > the new drive in the carrier. > 3. Wait a minimum of 30 seconds between taking the failed drive out and > inserting the new drive and carrier. > 4. Slide the new drive into the same slot and lock into place. > > I have also read that with the H700 controller, if the new drive is > replaced into the same slot as the removed failed drive, that the new > drive will be reinserted into the RAID virtual drive, and the hot spare > that was used will revert back to a hot spare again. > > The issue that I am having is that the newly installed drive is not > being recognized at all. > 1. The drive status indicator light and the drive activity light both > remain out. > 2. /var/log/messages show the drive removed, but not inserted. > Oct 30 12:17:30 earth Server Administrator: Storage Service EventID: > 2049 Physical device removed: Physical Disk 0:0:2 Controller 0, Connector 0 > 3. The hardware ESM log in OMSA shows the following two events (the > last two events listed) at the time the drive was removed. No > additional events show the new drive installed. > Ok;Fri Oct 30 12:17:33 2015;Drive 2 in disk drive bay 1 is operating > normally. > Critical;Fri Oct 30 12:17:33 2015;Drive 2 is removed from disk drive bay 1. > 4. The LCD panel on the front of the chassis remains an amber color with > the following message. > E1812 Hard drive 2 removed. Check drive > > I can't find anything that indicates I haven't done this replacement the > proper way. But need to figure out how to get this drive back on-line > and at least assigned as a hot spare. I have not power cycled the > server and would like to avoid doing that if possible. The only idea > that pops into my head right now is possibly some dust bunnies took up > residence in the hard drive connector slot as I slide the new drive into > place. So I am looking for ideas. What should I do to further diagnose > what my problem is and resolve it. Thanks. > > I only receive the daily digest of this mailing list, so please CC me > directly with any replies. Thanks. > > Jeff > > -- > > Jeff Boyce > Meridian Environmental > www.meridianenv.com > > _______________________________________________ > Linux-PowerEdge mailing list > [email protected] > https://lists.us.dell.com/mailman/listinfo/linux-poweredge > _______________________________________________ Linux-PowerEdge mailing list [email protected] https://lists.us.dell.com/mailman/listinfo/linux-poweredge