RE: K2600RS Blue Screen but power and clock crystals good

"'Mark & Mary Ann Weiss' [email protected] [KurzList]" <[email protected]>
Newsgroups gmane.music.equipment.kurzweil
Organization MW Communications Systems
Message-ID <70774EEBC1044DD2904E874935894491@QuadCore2>
During additional testing, I discovered the Power_Good line was pulsing
negative at 120 Hz. I traced back the sample to a unregulated DC rectifier.
Pulling that line high caused the K2600 to boot up.
I think it's dried out capacitors. So I'm replacing all capacitors in the
power supply. The large one, 33,000uF, is reading 21,000 on a GenRad
Digi-bridge.


[MW]  Today, I came into the studio and the display info was gone and only
the
blue seen backlight was visible.

If I power down and power up, after a delay, I hear the hard drive spin up
and head seeking, but the display remains blue/blank.