RE: K2600RS Blue Screen but power and clock crystals good
| Newsgroups | gmane.music.equipment.kurzweil |
|---|---|
| Organization | MW Communications Systems |
| Message-ID | <70774EEBC1044DD2904E874935894491@QuadCore2> |
During additional testing, I discovered the Power_Good line was pulsing negative at 120 Hz. I traced back the sample to a unregulated DC rectifier. Pulling that line high caused the K2600 to boot up. I think it's dried out capacitors. So I'm replacing all capacitors in the power supply. The large one, 33,000uF, is reading 21,000 on a GenRad Digi-bridge. [MW] Today, I came into the studio and the display info was gone and only the blue seen backlight was visible. If I power down and power up, after a delay, I hear the hard drive spin up and head seeking, but the display remains blue/blank.