Re: ID Search of EDACS system.
"This profile has been hijacked." <[email protected]> Fri, 17 May 2013 19:18:16 -0000
| Newsgroups | gmane.recreation.radio.hardware.uniden.bc785d |
|---|---|
| Message-ID | <[email protected]> |
Clark, Yes, I have the scanner programmed in the correct LCN order, when I program talkgroups and do an ID SCAN it works perfect. Signal strength is excellent on the control channel as well. Oh, I just discovered the problem! I didn't realize, I had iCall set to iCall Only! Thanks George --- In [email protected], Clark Rennie <c.rennie1@...> wrote: > > Are the LCNs in the correct order and is the control channel receiving > a signal ? > Hold on the control channel and do you hear the control channel noise ? > > Clark > > At 10:51 AM 5/4/2013, you wrote: > > >I just programmed an EDACS system into my BC785. However when I try an ID > >SEARCH it never stops on any talk-group. I know there are talk-groups > >active because I have a BC780XLT also in ID SEARCH and its finding & > >stopping on every talk-group that's active. > > > >What am I doing wrong on the BC785 while trying ID SEARCH on an EDACS system. > > > >Thanks > >George > >http://www.MilAirComms.com > ------------------------------------ If you have come here to find out about the 785D you have come to the right place! In fact the discussion of the BC-785D and how it works is the only acceptable topic on this list. Any discussion about anything other than the BC-785D is OFF TOPIC. I hope this is clear to all group members..